How the radiator calculator works
The heat a room needs depends mainly on its size, how warm you want it, and how quickly heat escapes through the walls, windows, floor and ceiling. The calculator starts from the room's volume and multiplies it by a heat loss figure for your level of insulation, then adjusts for the temperature you want and anything that makes the room colder.
watts = room volume (m³) × insulation factor × temperature factor × extras
temperature factor = (room temperature + 3) ÷ 24
extras = +10% each for north-facing, large windows, cold space above or below
BTU per hour = watts × 3.412
The insulation factors are 35 W/m³ for a well insulated room, 45 W/m³ for average and 60 W/m³ for poor. The temperature factor compares your room with a 21°C living room on a −3°C winter day, which is roughly what UK heating systems are designed around. A bedroom at 18°C needs about 12% less heat than a living room of the same size; a bathroom at 22°C needs about 4% more.
This is a rule of thumb, and it's good for choosing a replacement radiator or sizing one for an extension. If you're fitting a heat pump, the installer should do a proper room-by-room heat loss calculation instead.
Worked example: a 4m × 3.5m living room
- Volume: 4 × 3.5 × 2.4 = 33.6m³
- Average insulation: 33.6 × 45 = 1,512 watts
- Living room at 21°C, so the temperature factor is 1
- Heat needed: about 1,510 watts, or 1,512 × 3.412 = 5,160 BTU
If the same room faced north and had patio doors, add 20%: about 1,810 watts (6,190 BTU). You could split that across two smaller radiators, one under the window and one on another wall.
What ΔT50 means, and why heat pumps need bigger radiators
Radiator outputs are tested to a European standard (BS EN 442) and quoted at ΔT50, which means the water in the radiator is 50°C warmer than the room. That's about right for an older boiler running hot. Modern condensing boilers work best with cooler water, often around ΔT40, and heat pumps are cooler still, typically around ΔT30.
A radiator gives out less heat when it runs cooler. At ΔT40 it gives about 75% of its ΔT50 rating, and at ΔT30 only about 51%. So to get 1,500 watts into a room from a heat pump, you'd buy radiators rated at roughly 2,900 watts at ΔT50. The table in the calculator does this conversion for you.
| Water temperature | Output vs ΔT50 | Size up by |
|---|---|---|
| ΔT50 (traditional boiler) | 100% | – |
| ΔT40 (condensing boiler) | 75% | ×1.34 |
| ΔT30 (heat pump) | 51% | ×1.94 |
Choosing the radiator
- Single panel radiators are slim but give the least heat for their size.
- Double panel with fins (often called type 22 or K2) give roughly twice the heat of a single panel the same size, and are the usual choice for living rooms.
- Towel rails give much less heat than they look like they should, especially chrome ones. In a bigger bathroom you may need a towel rail and a small radiator.
- Put radiators under windows where you can. They warm the cold air coming off the glass before it sinks into the room.
Want to know what the heating costs to run? The energy cost calculator works out the running cost of any electric heater or appliance.
Frequently asked questions
What size radiator do I need for a 4m × 3.5m living room?
With a 2.4m ceiling and average insulation, about 1,510 watts (5,160 BTU). On a heat pump running at ΔT30 you would want radiators rated about 2,940 watts at ΔT50.
How many BTU do I need per square metre?
For a room with a 2.4m ceiling and average insulation, roughly 370 BTU (108 watts) per square metre for a living room, or about 320 BTU (95 watts) for a bedroom. Poorly insulated rooms need around a third more.
How do I convert watts to BTU?
Multiply watts by 3.412 to get BTU per hour. To go the other way, divide BTU by 3.412. So 1,000 watts is about 3,412 BTU.
What does ΔT50 mean on a radiator?
It means the output was measured with the radiator water 50°C warmer than the room. Most brochures quote ΔT50, so if your boiler or heat pump runs cooler, the radiator will give out less heat than its label says.
Do I need bigger radiators for a heat pump?
Usually, yes. Heat pumps run at lower water temperatures, around ΔT30, where a radiator gives about half its ΔT50 output. Your installer should work out room-by-room heat loss to size them properly.
Last reviewed November 2026. This calculator gives an estimate for guidance only.